首页 > 编程知识 正文

dell服务器进入安全模式,dell服务器开机提示错误怎么解决

时间:2023-05-05 12:49:31 阅读:268175 作者:3157

系统:CentOS 6.2 X86_64

内核:2.6.32-220.el6.x86_64

硬件:Dell PowerEdge R420

CPU:Intel(R) Xeon(R) CPU E5-2420 0 @ 1.90GHz

详细错误信息如下:

WARNING: at drivers/pci/intr_remapping.c:715 enable_intr_remapping+0×73/0x2af() (Not tainted)

Hardware name: PowerEdge R420

Your BIOS has requested that x2apic be disabled.

This will leave your machine vulnerable to irq-injection attacks.

Use ‘intremap=no_x2apic_optout’ to override BIOS request.

解决:

因ROM默认情况下不使用x2apic

1.忽略

2.使用’intremap=no_x2apic_optout’ 内核选项进行启动

如:

# vim /boot/grub/grub.conf

title CentOS (2.6.32-220.el6.x86_64)

root (hd0,0)

kernel /vmlinuz-2.6.32-220.el6.x86_64 ro root=/dev/mapper/VolGroup00-LogVol00_root rd_NO_LUKS rd_LVM_LV=VolGroup00/LogVol01_swap LANG=en_US.UTF-8 rd_NO_MD quiet SYSFONT=latarcyrheb-sun16 rhgb crashkernel=auto rd_LVM_LV=VolGroup00/LogVol00_root KEYBOARDTYPE=pc KEYTABLE=us rd_NO_DM intremap=no_x2apic_optout #添加该参数,重启服务器解决

initrd /initramfs-2.6.32-220.el6.x86_64.img

版权声明:该文观点仅代表作者本人。处理文章:请发送邮件至 三1五14八八95#扣扣.com 举报,一经查实,本站将立刻删除。