故障说明:向光纤交换机添加了新的Zone配置,但原始配置未更改,配置生效后,原始刀片式服务器出现PSOD紫屏现象。
psodscreenmayshowtheseerrors (xmeansthepcpunumber )。
pcux : no heart beat (2/2ipis接收) )。
x other PCPUs are in panic
@ blue screen : spincountexceeded (vport _ lock )- possible deadlock with PCPU x
spincountexceeded(vport_lock )- possible deadlock with PCPU x
savedbacktracefrom : pcpuxspinlockspinoutnmi
故障分析紫屏通过lpfc驱动启动操作系统版本: vmwareesxi6.0. 0构建- 692138 lpfc驱动版本:描述=emulexfibrechannelandfcoedriver 10.0
3359 support.hpe.com/hpsc/doc/public/display? s4ts.oid=null doclocale=en _ usdocid=MMR _ SF-en _ us 000013314 with frame
因此,我们建议您升级主机lpfc并将其驱动到10.7.170.0或更高版本
For vmware6.0554FLB最新版本lpfc驱动程序:
3359支持. hpe.com/hpsc/swd/public/detail? sp4ts.oid=5215387 switemid=MTX _ c7de 52b7c84 E4 f 309 e 2e 377 b8aswenvoid=4184 # tab 1
10.7.170.0版lpfc驱动程序:
3359支持. hpe.com/hpsc/swd/public/detail? switemid=MTX _ 458 b 501 AFA 4446 E8 ad9fcdb 03 d